How to choose temperature measurement points for LPDC mold thermocouple layout without misleading the process?
Thermocouples are the core of digital temperature control for molds. If the point is selected incorrectly, the collected temperature will have no reference value and mislead process adjustments.
1、 Quantitative specification for buried depth and distance of thermocouple cavity
The optimal distance between the thermocouple temperature probe and the surface of the mold cavity is 10-15mm, which can quickly respond to temperature changes in the mold cavity without being too close and damaged by thermal shock.
The burial depth is less than 8mm, the temperature fluctuates violently, the temperature drops sharply when the release agent is blown, and the reading is distorted; Greater than 20mm, response lag, the mold has exceeded the heat storage limit, and the temperature reading has not yet increased.
K-type thermocouple is the most universal model of LPDC, with a range of 0-1000 ℃ and accuracy that meets casting conditions; The high-temperature resistant sheath is made of stainless steel or ceramic sheath to prevent damage from aluminum liquid splashing.
The diameter of the temperature measurement point is reserved with a hole position of φ 6- φ 8mm, and the bottom of the hole is tightly attached to the sheath. The gap is filled with thermal conductive mud, and air insulation will cause the reading to be lower by 50-80 ℃, which is a high-frequency low-level error.
When Xinfeng Machinery is developing a temperature control scheme, it synchronously outputs thermocouple point drawings, indicating the burial depth and distance from the cavity size.
2、 Division of mandatory and optional points
Required locations: the hot spot near the sprue and the location of the thick hot spot in the casting. These two locations are the control points for solidification sequence and determine the risk of shrinkage.
Key monitoring points: exterior surface of the mold cavity, thin-walled filling end, used to determine the temperature at the filling front and predict cold insulation.
Auxiliary points: Template body, slider body, monitor whether the slider is overheated and sticky with aluminum; A point near the cooling water circuit is used to determine the cooling efficiency.
Not recommended location: Directly below the sealing tape on the parting surface, aluminum shavings squeezing and grinding can easily damage the thermocouple, resulting in high repair costs.
3、 Differences in temperature measurement solutions for overseas customers
Many projects in Southeast Asia do not embed thermocouples and rely on infrared thermometers for fixed-point sampling, resulting in scattered data and suitable for low requirement and low-cost castings.
North American automotive parts, each hot section is independently embedded with a thermocouple, the signal is connected to the die-casting machine PLC, the temperature upper and lower limits are written into the control plan, and the overtemperature lock machine is used.
European customers prefer multi-point distributed temperature measurement, coupled with closed-loop linkage of temperature control units, to automatically adjust cooling water and achieve unmanned steady-state production.
Middle Eastern thick walled castings are only arranged at two points, the sprue and the maximum hot spot, simplifying the system and reducing on-site maintenance difficulty.
4、 Common causes of thermocouple failure and reading distortion
The thermal conductive mud dried up and the air layer inside the hole remained low, causing the process personnel to mistakenly believe that the temperature was not enough and continue to reduce cooling, resulting in excessive heat storage.
The sheath is damaged, aluminum liquid seeps into the temperature measuring hole, the thermocouple is short circuited, and the reading jumps and fluctuates.
The buried point is too close to the cooling water circuit, and the measured temperature is the cooling water temperature, not the working temperature of the mold cavity, which completely loses its reference value.
Frequent mold repair, welding and polishing have damaged the thermocouple sheath, buried hidden faults, and caused wire breakage during production.
5、 Long tail traffic layout ideas
Thermocouples, temperature measurement points, and mold temperature monitoring belong to the category of digital process search, targeting process and automation engineers.
keywords: LPDC mold thermocouple placement、K type thermocouple for low pressure casting die;
Problem class: Thermocouple distance from cavity surface LPDC;
Comparison class: embedded thermocouple vs infrared gun for casting mold.
Suitable for digital and intelligent production line topics, undertaking high-end automation project traffic.
6、 Common misconceptions in the industry
Misconception 1: The closer the thermocouple is to the mold cavity, the more accurate it is. If the distance is too close, the mold release agent and aluminum liquid may impact it, resulting in a very short lifespan and huge fluctuations in readings.
Misconception 2: Infrared thermometers can replace pre embedded thermocouples. Infrared sensors measure the instantaneous surface temperature, which is affected by mold release agents and oxide scales and cannot reflect the temperature of the mold body.
Misconception 3: Just drill holes and bury them randomly, there are gaps in the holes, poor thermal conductivity, long-term low readings, misleading the process.
FAQ
Q: What is the recommended distance between the thermocouple temperature probe and the cavity?
A:10–15mm, Balancing response speed and service life.
Q: What are the mainstream models of LPDC thermocouples?
A: K-type, with a range that meets working conditions and high cost-effectiveness.
Q: Why is it necessary to fill the gap of the temperature measuring hole with thermal conductive mud?
A: Air insulation can cause significantly lower readings.
Q: Which locations are prioritized for pre embedded temperature measurement points?
A: Location of hot spots in sprues and thick castings.
Q: What are the shortcomings of infrared thermometers?
A: Due to interference from release agents and oxide scales, only instantaneous surface temperature can be measured.
Q: What are the thermocouple control requirements for North American customers?
A: Connect PLC, over temperature alarm and even lock machine, data traceability.
Q: What will happen if the thermocouple is buried next to the cooling water circuit?
A: The reading is biased towards water temperature and cannot represent the temperature of the mold cavity.
Q: What should be paid attention to when repairing and welding molds?
A: Confirm the position of the thermocouple in advance to avoid damaging the sheath during welding.
Copyright © Zhejiang Xinfeng Machinery Co., Ltd. All Rights Reserved.